Cleanroom Testing
NEBB-Certified Cleanroom Testing and Validation Services
Cleanroom Testing is a service that measures and validates the performance of cleanroom systems, ensuring that particle counts, air pressure, temperature, and humidity strictly comply with international standards such as ISO 14644 and GMP. VOV Group provides testing and Certification services utilizing highly precise measurement instruments. These procedures are conducted by our team of engineers certified by NEBB (USA), ensuring your facility is fully prepared for any level of Audit.
1. Airborne Particle Count Test
Testing air cleanliness and determining the cleanroom Class in accordance with the ISO 14644-1 standard
2. HEPA Filter Leak Test / PAO Test
Verifying the integrity of HEPA/ULPA filters to ensure no contaminated air leaks into the system
3. Airflow Velocity & Volume Test
Measuring airflow velocity and Air Change Rate to ensure compliance with design specifications
4. Room Pressurization Test
Checking the directional airflow between rooms to prevent Cross-Contamination
5. Temperature & Relative Humidity Test
Testing the uniformity of environmental controls to ensure suitability for specialized manufacturing processes
Why Choose VOV for Cleanroom Testing Services?
Meticulous attention to every cleanroom detail to ensure maximum performance for your industry

NEBB Certified Standards
We are one of the few companies in Thailand with engineers who have successfully passed the examinations and received international certification from NEBB (National Environmental Balancing Bureau)

Calibrated Instruments
Every instrument is strictly calibrated according to industry standards to ensure maximum accuracy and reliability

Comprehensive Report
We provide a clear, easy-to-read testing report that is fully documented and ready to be used as an immediate reference for any Auditor
Advanced Cleanroom Testing
International standard measurement services for official quality certification

Airborne Particle Count Test

Airflow Velocity & Volume Test

HEPA Filter Leak Test

Room Pressurization Test

Airflow Direction Test

Recovery Time Test

Lighting Intensity Test

Floor Conductivity Test

Sound Level Test

Temperature & Humidity Test

Airflow Visualization Test

Air Change Rate Test
Standards
Ensuring quality through globally recognized international standards







Our Valued Clients
Trusted by leading organizations, both domestically and internationally











20+
Years
EXPERIENCE
500,000+
Square Meters
CLEANROOM TESTED
1,000,000+
Units
OF HEPA/ULPA FILTERS TESTED
500+
Clients
PROJECTS COMPLETED
Dedicated to elevating testing standards with advanced technology and professional engineers
We help our clients build confidence in their cleanroom facilities by ensuring strict compliance with international standards. We are fully equipped to deliver our services using specialized instruments and a team of experts
FAQ
According to international standards, it is recommended to conduct Cleanroom Testing at least once a year, or every 6 months for high-level cleanrooms (e.g., ISO Class 5 and above). Retesting is also required whenever HEPA filters are replaced or structural modifications are made to the room.
NEBB (National Environmental Balancing Bureau) is a premier international association based in the USA that establishes standards for testing HVAC and cleanroom systems. Utilizing a NEBB-Certified firm guarantees the accuracy of the testing process and is globally recognized by Auditors.
Consult with Our Cleanroom Testing Experts
Let our NEBB-certified engineering team help plan and test your cleanroom according to standards, ensuring international-level accuracy and compliance